Caution care and maintenance – Levenhuk D670T Digital Trinocular Microscope User Manual

Page 5

Advertising
background image

Never look at the sources of bright light or lasers through the camera or the microscope: it will
cause PERMANENT RETINAL DAMAGE and may lead to BLINDNESS!
Do not disassemble the camera on your own.
Protect the camera from moisture; do not use it in rainy weather.
Protect the camera from impacts or excessive pressure.
Do not overtighten the locking screws.
Keep the camera away from hazardous environment, home and car heaters, incandescent lamps
or open fire.
When cleaning the lenses, first blow any dust or debris off the surface or wipe them off with a
soft brush. Then wipe the lens with a soft cleaning cloth dipped in lens cleaning fluid.
Never touch the optics with your fingers.

Caution

Care and maintenance

After unpacking your microscope and before using it for the first time check for durability of
every component and connection. Do not apply excessive pressure, lest you break your
instrument. Be careful during your observations; always replace the dust cover after you are
finished with observations to protect your microscope from dust and stains. Do not try to take
your microscope apart, as you might damage the intricate optical system within.

Store the microscope in a dry and cool place, away from possible impacts and dust. Do not try to
perform repairs of any kind on this instrument – contact a Levenhuk service center instead. If
you are not using your microscope for extended periods of time, store the objective lenses and
eyepieces separately from the microscope itself.

Connect the camera to your PC via a USB-cable that also acts as a power cable, so you do not
have to plug it into a power source.
Compatible OS: Windows 2000/XP/2003/Vista

Camera model

Max. resolution (for still images)

Megapixels

Sensor

Dimensions (cylinder unit maximum diameter), mm

Pixel size

Sensitivity, V/lux.sec@550 nm

Mounting location

Image format

Field of view diameter

Spectral range

Exposure

White balance

Exposure control

Software image control

Interface

System requirements

Software

Shell

Power source

Temperature range

С510 NG
2592x1944
5.0
1/2.2° CMOS
50
2.2μm x 2.2μm
1.2
Eyepiece tube (replaces the eyepiece)
BMP, TIFF, JPG, PICT, SFTL, etc.
18 mm
400 nm – 650 nm
ERS
Auto/manual
Auto/manual
Image size, brightness, exposure control
USB 2.0, 480 Mb/s
Windows 2000/XP(SP2)/2003/Vista; USB port
USB 2.0 driver, software for image viewing and editing
Metal cylinder, painted black
USB 2.0 cable
-30... 70 °С (-22... 158 F)