SINGLE PHASE SCHEMATIC DIAGRAM for LGJ

1666

CONTROL WIRING

Standard C2 or B2 Wiring
Model MGJ operators are shipped from the factory
with jumper set for C2 wiring, which requires constant
pressure on button to close the door. If momentary
contact in close direction is desired (B2 wiring) you
must include an entrapment protection device. See
close control jumper setting below.

Constant pressure on close (C2 wiring)
Red jumper wire was placed on terminal #2 in
the electrical enclosure. The operator will require
constant pressure on close control in order to keep
door moving in the close direction.

Momentary contact on close (B2 wiring)
Move red jumper wire from terminal #2 to terminal
#3. The operator will require only momentary
contact to close the door.

LOCATING THE CONTROL STATION
All operators are supplied with some type of control station. Generally a three button station
(OPEN/CLOSE/STOP) is provided. A two-position key switch or control station (OPEN/CLOSE) may be added or
substituted when requested at the time of order. Mount the control station near the door.

WARNING

CAUTION

WARNING

WARNING

INSTALL THE CONTROL STATION WHERE THE

DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND

ITS HARDWARE. IF CONTROL STATION CANNOT BE

INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY

DEVICE OTHER THAN THE CONTROL STATION IS

USED TO ACTIVATE THE DOOR, A REVERSING

EDGE MUST BE INSTALLED ON THE BOTTOM OF

THE DOOR. FAILURE TO INSTALL A REVERSING

EDGE UNDER THESE CIRCUMSTANCES MAY

RESULT IN SERIOUS INJURY OR DEATH TO

PERSONS TRAPPED BENEATH THE DOOR.

W A R N I N G

TO PREVENT ENTRAPMENT

DO NOT START DOOR DOWNWARD

UNLESS DOORWAY IS CLEAR

OPEN

CLOSE

STOP

Control Station

WARNING Notice

Push

Buttons

IMPORTANT: Mount WARNING NOTICE beside or
below the push button station.

MOUNT WARNING NOTICE

DETERMINE WIRING TYPE
Refer to the wiring diagram located on the inside cover the electrical box to determine the type of control wiring.

SPECIAL CONTROL WIRING

If your operator was shipped from the factory with
non-standard control wiring or with optional
accessories that require additional instructions, refer
to the wiring diagram(s) indicated in the special
control wiring data box. When a replacement wiring
diagram is present, wiring diagrams in this manual
will not apply. Refer only to the replacement wiring
diagram for all connections.

IMPORTANT NOTE: If your wiring diagram is
missing, or you are unsure of the wiring type for
your operator, contact the customer service
department @ 1-800-528-2806.

MODEL MGJ

Standard G2 Wiring
Model LGJ operators are supplied with type G2 control
wiring. Study the control features list below to
determine the features and type of control equipment
that may be used with your operator.

Entry Controls:
OPEN control requiring maintained contact.
OPEN control requiring only momentary contact.
CLOSE control requiring maintained contact.
CLOSE control requiring only momentary contact.
OPEN/CLOSE single control requiring momentary
contact..
STOP control requiring momentary contact.

Safety Devices:
External Interlock switch to disable all control
pneumatic safety (N.C.) to STOP while closing Safety
Device to REVERSE while closing Door Lock Sensing
Circuit.

Operational Features:
REVERSE (if closing) with momentary contact on
OPEN.
AUTOMATIC TIMER to CLOSE from any device.
AUTOMATIC TIMER to CLOSE from selected devices.
DELAY REVERSE in either direction for 1 second.
STOP after maximum run time is exceeded.

Note:
Refer to LGJ control connection diagrams on page 15.

MODEL LGJ