Operation and maintenance, Maintenance + battery – LiftMaster RSW12V Residential / Light Commercial Swing Gate Operator with Battery Backup User Manual

Page 29

Advertising
background image

28

OPERATION AND MAINTENANCE

» MAINTENANCE + BATTERY

MAINTENANCE

Disconnect all power to the operator before servicing.

CHECK AT LEAST ONCE EVERY

DESCRIPTION

TASK

MONTH

6 MONTHS

3 YEARS

External Entrapment Protection System

Check and test for proper operation

X

Photoelectric Sensors

Check and test for proper operation

X

Warning Signs

Make sure they are present

X

Manual Disconnect

Check and test for proper operation

X

Sprockets and Chains

Check for excessive slack and lubricate

X

Gate

Inspect for wear or damage

X

Accessories

Check all for proper operation

X

Electrical

Inspect all wire connections

X

Chassis Mounting Bolts

Check for tightness

X

Operator

Inspect for wear or damage

X

Batteries

Replace

X

NOTES:
• Severe or high cycle usage will require more frequent maintenance checks.
• It is suggested that while at the site voltage readings be taken at the operator.

Using a digital voltmeter, verify that the incoming voltage to the operator it is
within ten percent of the operator’s rating.

BATTERY

The battery should be replaced every three years. Use only LiftMaster part 29-NP712
for replacement batteries. The operator comes with one 7AH battery. A second 7AH
(29-NP712) battery may be added or one 33AH (A12330SGLPK) may be used in
place of the 7AH batteries. The batteries contain lead and need to be disposed of
properly.