Allegro Industries 9846 User Manual

Page 7

Advertising
background image

S P E C I F I C A T I O N S

The table shows the maximum allowable number of tight-fitting respirators or loose-fitting hoods.

MODEL

NUMBER

PART

NO.

MAX NO.

RESP.

MAX NO.

HOODS

POWER

REQUIRED

LBS

HP

PSI

CFM

A-300

9806

1

0

5.5A 115/230V

30

¼

0 – 15

0 – 5

A-750

9821

2

1

8.3A 115/230V

53

¾

0 – 15

0 – 10

A-1500TE

9832

3

2

16A 115/230V

97

1 ½

0 – 15

0 – 20

A-1500EX

9833*

3

2

10.6A 115/230V

122

1 ½

0 – 15

0 – 15

A-3000ATE

9846

6

4

30A 115/230V

203

3

0 – 15

0 – 32

A-4000AD

9850

4

3

75 cfm@80 psig

73

4

(3,7kW)

0 – 15

0 – 20

*Single Phase Explosion Proof Motor, complete with Hazardous location type plug and receptacle.


I N S P E C T I O N


ALL PUMPS:
Regular inspection, cleaning filters, and “flushing” may prevent extensive repairs. Dirty or clogged filter elements
can cause overheating (in excess of 200

°F) and possible pump failure.


It is normal for the pump surface and immediate output air temperatures to reach 200

°F when the unit is run

continuously under a heavy load or high pressure settings.
o

If there is evidence of overheating or excessive noise, stop immediately.

o

High-pressure operation will shorten pump’s life.

o

Keep external surfaces clean for proper heat dissipation.

o

Do not allow pump to operate in ambient air temperatures excess of 40

°C (104°F).


Failures due to pressure buildup are due to the following:
o

Improper setting of pressure relief valve

o

Leaks in airline connections

o

Damaged filter canister threads

o

Collapsed or kinked air lines, dirty filter elements

o

Vanes sticking in the rotor slots



ELECTRICAL MOTORS:

Some electrical motors are equipped with a thermal protector that shuts motor down automatically when subjected
to mechanical or electrical overloads. Ensure electrical power source corresponds to what is on the motor name
plate.


AIR DRIVEN MOTORS:

The air coming out of the discharge port will cool as it expands. It is important that the PVC extension (included
with the blower) is used to extend the muffler from the motor discharge port. This will help prevent ice from
forming on the muffler due to moisture in the air.

5

Advertising