FOR MORE INFORMATION, PLEASE CALL 210-533-1231

Revised 3/09

8065L PNEUMATIC
LOCKING SYSTEM

The 8065L series covers several
versions of a system designed for
locking, unlocking and propelling
sliding doors in safety vestibules,
in dayrooms or in high-traffic
corridors.

Each 8065L model utilizes
pneumatic cylinders to operate the
door. Doors are locked at top and
bottom in both the open and
closed positions by means of a
concealed vertical lock bar at the
rear jamb of the door. The vertical
lock bar is deadlocked at a third
locking point inside the horizontal
cover box above the door.
Standard clear door opening
widths available are 3'-0" to 4'-6".

FUNCTION:

ELECTRIC - A remote switch
activates pneumatic cylinders
which raise a vertical lock bar and
propel the door open or closed.

MECHANICAL - Manual
unlocking is provided for each
device. After being manually
released, door movement is by
hand. The door automatically
deadlocks when moved to the fully
open or closed position.

8065L

PNEUMATIC LOCKING

SYSTEM

TECHNICAL DATA:

• COVER BOX:

1' 0-3/4" H x 7-1/2" D

• COVER BOX MATERIAL:

7 gauge steel plate

• HINGED PANEL:

10 gauge steel

• DOOR ROLLERS:

3" diameter, with
sealed bearings

• VERTICAL LOCK BAR

DIMENSIONS:
5/8" SQ by full height
of door

• FINISH: Prime paint
• DOOR HANGER:

7 gauge steel plate

• ELECTRICAL: 3.5 watts
• WIRE REQUIREMENTS:

Minimum of five 24 volt conductors
are required between the
control point and the door,
except for those models
having the letter “K”
(keyswitch) in the suffix.
Keyswitch models require
minimum six conductors.

• AIR REQUIREMENTS:

Air consumption varies with
door size at 80 PSIG.