1

2

3

4

5

6

7

8

9

10

12

13 14

15

11

1. Optional 24V DC Power Input

Connect to a 24V DC Power Source when lower voltage input is
desired.

2. Chime Selection Switch

Sets the amount of chimes heard when the Chime Trigger is
activated. 2 times or 4 times.

3. Microphone Priority Dipswitch

Sets mic ducking for the 4 Mic inputs.

On Mic signal overrides sources (Source signal interrupted

by Mic Signal)

Off Mic signal mixes with sources (Source signal and Mic

Signal output simultaneously.)

4. Chime Volume

Sets the volume level of when Chimes are triggered.

5. XLR Pre Out

Balanced XLR output attenuated by Master Volume control.

Note: Output level is affected by Source and Mic gain, and Bass and

Treble controls.

6. Speaker Output Connector

Connections for 50V, 70V, 100V, or 4Ω speakers attenuated by
Master Volume

Note: Output level is affected by Source and Mic gain, and Bass

and Treble controls.

7. IEC Power Cord

Detachable power for amplifier.

8. AC Fuse

Replaceable main power fuse.

9. Phantom Power Switches

Off Unpowered Mic

On Provides phantom power to microphones with this

capability.

10. Microphone 1-4

Balanced XLR input for microphones.

11. Microphone Gain Controls

Sets the gain level for the appropriate mic input

12. Source Inputs

Unbalanced RCA stereo input for audio sources.

13. Rec Line Output

Unbalanced RCA stereo fixed level output.

Note: Output level is affected by Source and Mic gain, and Bass and

Treble controls.

14. Pre Out / Amp In

Unbalanced RCA mono output and input attenuated by Master
Volume control. Jumper can be removed for use with External
Audio Processor.

Note: Output level is affected by Source and Mic gain, and Bass and

Treble controls.

15. Chime Remote Trigger

Connect the output of a door or other triggering source

Advertising