Chime surface mount, Chime with universal mounting plate, Chime direct mount – System Sensor CH1224 and CH1224W Electronic Chime_Sounder User Manual

Page 3: Mounting diagrams: mounting, Figure 1

Advertising
background image

D900-00-00 3 I56-0003-004R

4-INCH BACK BOX

BBS, BBSW

A

A

LOCKING RIB SLOT

LOCKING RIB

Chime surface mount:

1. Mount skirt to back box with screws A.
2. Complete field wiring.
3. Insert locking rib on unit into slot on skirt.
4. Press into skirt; unit will make a “click” when it has locked into

place.

(NOTE: Chime and skirt may also be mounted to a 2-inch box using
screws B instead of screws A.)

���������������

�����������������

�������������������

����������������

�����������

������������������������������

Chime with universal mounting plate:

1. Mount plate to back box using screws A.
2. Complete field wiring.
3. Insert locking rib into slot on plate.
4. Press into plate, unit will make a “click” when it has locked into

place.

2-INCH BACK BOX

WALL OPENING MUST

EQUAL PLATE OPENING

S-MP, S-MPW

LOCKING RIB SLOT

LOCKING RIB

B

B

Chime direct mount:

1. Mount plate to back box using screws B.
2. Break off four tabs from unit.
3. Complete field wiring.
4. Insert locking rib into slot on plate.
5. Press into plate; unit will make a “click” when it has locked into

place.

Screw types used for mounting:
A = 8-32 ×

3

4

flat head

B = 6-32 × 1

5

16

pan head

Mounting Diagrams:

Mounting

1. The chime is intended for mounting to a standard 1

1

/

2

″ deep single-

gang box which allows sufficient clearance for conduit entrance.

2. The chime is compatible with DC line supervision, is polarized, and

has terminals marked with polarity. Apply positive supply voltage to
the (+) terminal and negative supply voltage to the (–) terminal. (See
Figure 1.)

3. Mount the chime to the electrical outlet box using the two mounting

screws supplied.

4. Field repair of the chime should not be attempted. Return to factory

for repair or replacement.

NOTE: Shown with control panel in alarm. Panel polarity reversed in

supervisory condition.

Figure 1:

����

�������

�����

��

��������

�������

��

���

��

����

������

A0179-00

A0180-00

Figure 2: Removal of horns and strobes from mounting
plates:

To remove units from mounting plates, insert screwdriver as shown to
unlock snap. While pushing in screwdriver to release the snap, pull back
on the chime/sounder. Hinge the chime/sounder module, disengage the
Locking Rib, and lift the chime/sounder away from the mounting plate.

PLASTIC SNAP LEVER

TAB SLOT

TAB

INSERT REMOVAL TOOL

A0204-00

A0115-00

A0178-00

Advertising