Strobe or Horn/Strobe with universal mounting plate:
1. Mount adapter plate to back box with screws B.
2. Complete field wiring.
3. Secure unit to plate with screws A.

Strobe or Horn/Strobe surface mount:
1. Mount adapter plate

and back box skirt to

back box with screws B.

2. Complete

field wiring.

3. Secure unit to

skirt with screws A.

Mounting Diagrams:

The horn and/or strobe will not work without power. The horn/strobe gets its

power from the fire/security panel monitoring the alarm system. If power is cut off for

any reason, the horn/strobe will not provide the desired audio or visual warning.

The horn may not be heard. The loudness of the horn meets (or exceeds) current

Underwriters Laboratories’ standards. However, the horn may not alert a sound

sleeper or one who has recently used drugs or has been drinking alcoholic beverages.

The horn may not be heard if it is placed on a different floor from the person in hazard

or if placed too far away to be heard over the ambient noise such as traffic, air condi-

tioners, machinery or music appliances that may prevent alert persons from hearing

the alarm. The horn may not be heard by persons who are hearing impaired.

NOTE: Strobes must be powered continuously for horn operation.

The signal strobe may not be seen. The electronic visual warning signal uses an

extremely reliable xenon flash tube. It flashes at least once every second. The strobe

must not be installed in direct sunlight or areas of high light intensity (over 60 foot

candles) where the visual flash might be disregarded or not seen. The strobe may

not be seen by the visually impaired.

The signal strobe may cause seizures. Individuals who have positive photoic

response to visual stimuli with seizures, such as persons with epilepsy, should avoid

prolonged exposure to environments in which strobe signals, including this strobe,

are activated.

The signal strobe cannot operate from coded power supplies. Coded power

supplies produce interrupted power. The strobe must have an uninterrupted source

of power in order to operate correctly. System Sensor recommends that the horn and

signal strobe always be used in combination so that the risks from any of the above

limitations are minimized.

WARNING

The Limitations of Ceiling Mount Horn/Strobes

Three-Year Limited Warranty

System Sensor warrants its enclosed horn. strobe, or horn/strobe to be free from

defects in materials and workmanship under normal use and service for a period

of three years from date of manufacture. System Sensor makes no other express

warranty for this horn, strobe, or horn/strobe. No agent, representative, dealer, or

employee of the Company has the authority to increase or alter the obligations or

limitations of this Warranty. The Company’s obligation of this Warranty shall be

limited to the repair or replacement of any part of the horn, strobe, or horn/strobe

which is found to be defective in materials or workmanship under normal use and

service during the three year period commencing with the date of manufacture. After

phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return

Authorization number, send defective units postage prepaid to: System Sensor,

Returns Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174.

Please include a note describing the malfunction and suspected cause of failure. The

Company shall not be obligated to repair or replace units which are found to be de-

fective because of damage, unreasonable use, modifications, or alterations occurring

after the date of manufacture. In no case shall the Company be liable for any conse-

quential or incidental damages for breach of this or any other Warranty, expressed

or implied whatsoever, even if the loss or damage is caused by the Company’s neg-

ligence or fault. Some states do not allow the exclusion or limitation of incidental or

consequential damages, so the above limitation or exclusion may not apply to you.

This Warranty gives you specific legal rights, and you may also have other rights

which vary from state to state.

A

B

Screw types used for mounting:
A = #8 plastite
B = 8-32 ×

3

/

4

pan head

A

B

4Ч4Ч1

1

2

BBSCW (white)
BBSC (red)

FCC Statement

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable pro-
tection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and

used in accordance with the instruction manual, may cause harmful interference to radio commu-
nications. Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.

A0317-00

A0318-00

Please refer to insert for the Limitations of Fire Alarm Systems

Advertising