System Sensor warrants its enclosed speaker/strobe to be free from defects
in materials and workmanship under normal use and service for a period
of three years from date of manufacture. System Sensor makes no other
express warranty for this speaker/strobe. No agent, representative, dealer,
or employee of the Company has the authority to increase or alter the
obligations or limitations of this Warranty. The Company’s obligation of
this Warranty shall be limited to the repair or replacement of any part of
the speaker/strobe which is found to be defective in materials or work-
manship under normal use and service during the three year period com-
mencing with the date of manufacture. After phoning System Sensor’s
toll free number 800-SENSOR2 (736-7672) for a Return Authorization
number, send defective units postage prepaid to: System Sensor, Returns

SpectrAlert Speaker/Strobes have been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio

If either of the voltage select or power select shunts is not plugged into
one of the appropriate option positions, the speaker will not sound and
there will be no trouble indication at the panel. Always make sure that the
individual speakers are tested after installation per NFPA regulations.
The speaker may not be heard. The loudness of the speaker meets (or
exceeds) the current Underwriters Laboratories’ standards. However, the
speaker may not attract the attention of a sound sleeper or one who has
recently used drugs or has been drinking alcoholic beverages. The speaker
may not be heard if it is placed on a different floor from the person in haz-
ard or if placed too far away to be heard over the ambient noise. Traffic,
air conditioners, machinery, or music appliances may prevent even alert
persons from hearing the alarm. The speaker may not be heard by persons
who are hearing impaired.

WARNING

The Limitations of Speaker/Strobes

The signal strobe may not be seen. The electronic visual warning signal
uses an extremely reliable xenon flash tube. It flashes at least once every
second. The strobe must not be installed in direct sunlight or areas of high
light intensity (over 60 foot candles) where the visual flash might be disre-
garded or not seen. The strobe may not be seen by the visually impaired.
The signal strobe may cause seizures. Individuals who have positive
photoic response to visual stimuli with seizures, such as persons with epi-
lepsy, should avoid prolonged exposure to environments in which strobe
signals, including this strobe, are activated.
The signal strobe cannot operate from coded power supplies. Coded
power supplies produce interrupted power. The strobe must have an
uninterrupted source of power in order to operate correctly. System Sensor
recommends that the horn and signal strobe always be used in combina-
tion so that the risks from any of the above limitations are minimized.

Please refer to insert for the Limitations of Fire Alarm Systems

Figure 4. Knockout plug removal
1. If a rear conduit entry is required, remove the knockout

plug using a flat blade screwdriver as shown in Figure
4. Strike sharply with a hammer to pierce the wall of
the knockout plug. Move to an adjacent wall section and
repeat until the plug falls out. Make sure that the back
box is supported adequately during this operation to
avoid injury.

2. To meet weatherproof or outdoor listing, the conduit

entrance must be gasketed.

3. Install

3

/

4

˝ NPT plugs (2) into unused conduit openings.

A0341-01

FCC Statement

frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communica-
tions. operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the
interference at his own expense.

Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174.
Please include a note describing the malfunction and suspected cause.
The Company shall not be obligated to repair or replace units which are
found to be defective because of damage, unreasonable use, modifica-
tions, or alterations occurring after the date of manufacture. In no case
shall the Company be liable for any consequential or incidental damages
for breach of this or any other Warranty, expressed or implied whatsoever,
even if the loss or damage is caused by the Company’s negligence or fault.
Some states do not allow the exclusion or limitation of incidental or con-
sequential damages, so the above limitation or exclusion may not apply to
you. This Warranty gives you specific legal rights, and you may also have
other rights which vary from state to state.

Three-Year Limited Warranty

Advertising