System Sensor WTP and WTPW Weatherproof Plate User Manual

Spectralert advance weatherproof plate

Advertising
background image

SpectrAlert Advance
Weatherproof Plate

INSTALLATION AND MAINTENANCE INSTRUCTIONS

3825 Ohio Avenue, St. Charles, Illinois 60174

1-800-SENSOR2, FAX: 630-377-6495

www.systemsensor.com

Note: This product meets NEMA 3R for indoor or outdoor use to provide a
degree of protection against falling dirt, rain, sleet, or snow; and that will be
undamaged by the external formation of ice on the enclosure.
GENERAL DESCRIPTION
For installation with SpectrAlert Advance outdoor or outdoor replacement (-R)
horns, strobes and horn strobes. This accessory plate allows an outdoor unit
to be flush mounted on a number of different surfaces including brick, ce-
ramic tile, concrete and masonry brick.. The weatherproof plate is offered in
red and white. The weatherproof plate is sold separately from the device.
INSTALLATION:
1. The WTP series of products may be used indoors or outdoors. They

must be installed using the proper SpectrAlert Advance K series product.
Do not attempt to use weatherproof plates with devices other than those
specified for use with this product.

2. Attach device mounting plate to WTP. The WTP is compatible with

4x4x1-

1

/

4

” and 2x4x1-

1

/

2

” back boxes.

a. Place the device mounting plate on the WTP (See Fig. 1) and secure

using the four #6-32 x

3

/

8

” pan head screws (A).

b. Secure the WTP and device mounting plate assembly to the back box

(See Fig 2) using the two #8-32x2” pan head screws when using a
4x4” back box (B). When using the 2x4” back box (See Fig 3), secure
the WTP assembly using the two #6-32x2” pan head screws (C).

c. Tighten screws until the WTP assembly contacts the wall surface

evenly.

3. It is the responsibility of the installer to make sure that all openings and

connections are sealed properly. An outdoor rated silicon caulk (not
supplied) may be applied around the WTP to fill in around grout tiles or
uneven surfaces.

4. Connect field wiring to terminals. Please follow instruction manual sup-

plied with the device.

5. Attach the device to the mounting plate by hooking the tabs on the de-

vice housing into the grooves on the mounting plate. Then, swing prod-
uct into position to engage the pins on the device with the terminals
on the mounting plate. Make sure that the tabs on the back are fully
engaged with the mounting plate.

6. Secure the device to the WTP (See Fig. 4) by tightening the single mount-

ing screw(D) attached to the front of the device housing. For tamper
resistance, the captivated screw may be replaced with the Torx screw
supplied with the device.

SS-110-003

1

I56-3386-002R

I56-3386-00

2R

SPECIfICATIONS
Operating Temperature:

-40° F to 151° F (-40° C to 66° C)

Enclosure Rating:

Meets NEMA 3R, IP22 rating requirements

For use with models WTP and WTPW

Note: This product may only be installed in conjunction with an outdoor SpectrAlert Advance Horn, Strobe or Horn Strobe
Models: HRK-R, SRK-R, SRHK-R, SWK-R, SWHK-R, P2RK-R, P2RHK-R, P2WK-R, P2WHK-R, P4RK-R, HRK, SRK, SRK-P, SRHK, SRHK-P, SWK, SWK-P,
SWHK, SWHK-P, P2RK, P2RK-P, P2RHK, P2RHK-P, P2WK, P2WK-P, P2WHK, P2WHK-P, P4RK, P4WK
(-R models ship minus the outdoor back box, stan-
dard outdoor and -P models ship with an outdoor back box which is not needed when using the weatherproof plate).
Notice: This manual shall be left with the owner/user of this equipment.

fIGURE 1: WTP AND DEvICE MOUNTING PLATE ASSEMbLy.

A0425-00

WALL PRODUCT

LENGTH

WIDTH

DEPTH fROM WALL

Horn Strobe

6.90˝

5.90˝

2.8˝ Including Strobe Lens

Horn

6.90˝

5.90˝

1.6˝ Including Horn

Advertising