Three-Year Limited Warranty

System Sensor warrants its enclosed sounder/strobe to be free from
defects in materials and workmanship under normal use and service for a
period of three years from date of manufacture. System Sensor makes no
other express warranty for this sounder/strobe. No agent, representative,
dealer, or employee of the Company has the authority to increase or alter
the obligations or limitations of this Warranty. The Company’s obliga-
tion of this Warranty shall be limited to the repair or replacement of any
part of the sounder/strobe which is found to be defective in materials or
workmanship under normal use and service during the three year period
commencing with the date of manufacture. After phoning System Sensor’s
toll free number 800-SENSOR2 (736-7672) for a Return Authorization
number, send defective units postage prepaid to: System Sensor, Repair

Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174.
Please include a note describing the malfunction and suspected cause
of failure. The Company shall not be obligated to repair or replace units
which are found to be defective because of damage, unreasonable use,
modifications, or alterations occurring after the date of manufacture. In
no case shall the Company be liable for any consequential or incidental
damages for breach of this or any other Warranty, expressed or implied
whatsoever, even if the loss or damage is caused by the Company’s neg-
ligence or fault. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion
may not apply to you. This Warranty gives you specific legal rights, and
you may also have other rights which vary from state to state.

System Sensor’s sounder and signal strobe is designed to provide fire and
security hazard warning.
The strobe is for supplementary signaling use only.
The sounder or sounder/strobe combination will not work without
power.
The sounder or sounder/strobe gets its power from the fire or
security panel monitoring the alarm system. If power is cut off for any
reason, the sounder or sounder/strobe combination will not provide the
desired audible or visual warning.

The signal strobe may not be seen. The electronic visual warning signal
meets or exceeds current Underwriters Laboratories’ standard 1638. The
visual warning signal is suitable for direct viewing and must be installed
within an area where it can be seen by building occupants. The strobe
must not be installed in direct sunlight or areas of high light intensity
where the visual flash might be disregarded or not seen. The strobe may
not be seen by the visually impaired.
The signal strobe may cause seizures.
Individuals who have a posi-
tive photic response to visual stimuli with seizures, such as epileptics,
should avoid prolonged exposure to environments in which strobe signals,
including this strobe, are activated.

WARNING

The Limitations of Sounders and Strobes

Installation with SSK451 Multi-signaling Accessory
This optional strobe can be purchased separately and is
easily added to the SSK451 accessory.

Please refer to insert for the Limitations of Fire Alarm Systems

D200-51-00

4

I56-2716-001R

©2004 System Sensor

The PS24LO strobe will be mounted on top of the sounder,
on the left-hand side of the SSK451. Place one mounting
spacer between the SSK451 and the strobe adapter plate
at each screw attachment location. Attach the adapter plate,
spacer and SSK451 to the left-hand side of the double-gang elec-
trical outlet box with two mounting screws.

Slide the strobe terminals directly into the two slots in the
adapter plate and SSK451. The positive lug, which will be col-
ored

red, must be installed into the top slot.

Grasp the catch area on the top of the strobe and squeeze while
applying inward force. Repeat for the catch area on the bottom
of the strobe.

Make sure the strobe catches fully engage into the slots in the
adapter plate and that no gap appears at the interface between
the strobe and adapter plate.

Optional SMOKE Strobe Lens
NOTE:
To meet the code requirements of certain jurisdictions, an
optional SMOKE lens can be purchased separately.

SMOKE lens, wall mount

PS12/24SLENSW

SMOKE lens, ceiling mount

PS12/24SLENSC

Please follow the instructions enclosed with the lens for proper
installation of the lens to the strobe.

RED TERMINAL

ON TOP

H0485-00

Figure 3: