Open Problem Reports and Feature Exceptions

OmniSwitch 6800/6850/9000—Release 6.1.3.R01

page 53

PR 107284

Supplicant and non-supplicant are not displayed together on the same front page for 802.1x on an OS6850.

Workaround: View the non-supplicants on a different page - 802.1x non supplicant page. Display Issue
Only.

PR 107315

A duplicate slot in a stack of switches will not display the switch picture in the WebView > Chassis Mgmt
> Chassis homepage.

Workaround: Remove the duplicate slot.

PR 107529

WebView Networking > IP > BGP > Policy Route Maps Modify help "local Preference Value" hyperlink
is broken.

Workaround: There is no known workaround at this time.

PR 107530

When using the Netscape browser to access the WebView > Policy > Policy > Ports page after clicking on
either "Previous" or "Next" buttons and then clicking on the "Refresh" button, a "method not allowed"
error is displayed.

Workaround: Click on the "Ports" menu to refresh.

Autonegotiation

Problem Reports

PR 86826

On an OS6800/OS9000, when autonegotiation is disabled and speed is forced to 10 Mbps, copper ports
may confuse with a forced 100Mbps link partner and can detect a false link UP. Traffic may not pass in
this condition.

Workaround: Enable autonegotiation for this copper port and configure desired speed and duplex
settings.