Break wire as shown for
supervision of connection.
DO NOT allow stripped wire
leads to extend beyond
switch housing. Do NOT
loop wires.

D770-29-00

3

I56-1570-003R

Figure 3. Wiring AFD to bell:

BELL

BELL

POWER SOURCE

A B

C

OM

POWER
TERMINALS

AUX RELAY
TERMINALS

Figure 7. Wiring the AFD to a panel and other device:
Leave the Relay Wires installed under the Power Terminals and connect the
panel initiating loop wires as shown below. The AFD requires power to
operate, therefore connect the FACP initiating loop wires to the Power
Terminals and Relay Wires as shown.

EOL

OR NEXT
DEVICE

FACP

POWER SOURCE

BELL

BELL

A B

C

OM

POWER
TERMINALS

AUX RELAY
TERMINALS

RELAY
WIRES

Figure 6. Wiring the AFD to a panel:
Leave the Relay wires installed under the Power Terminals and connect the
panel initiating loop wires as shown below.

OR NEXT
DEVICE

POWER
TERMINALS

AUX RELAY
TERMINALS

A B COM

EOL

FACP

RELAY
WIRES

TO NEXT MODULE
OR EOL

INTELLIGENT

MODULE

FACP

A B COM

POWER
TERMINALS

AUX RELAY
TERMINALS

RELAY
WIRES

Figure 8. (2 Wire Addressable) Wiring the AFD to an addressable

panel using the SLC loop wires for power:
Remove the Relay Wires from under the Power Terminals. Connect these
wires to the Addressable Module.

NOTE:

Consult FACP Manufacturers’ Compatibility Guide prior to instal-
lation.

Figure 4. (4 Wire Addressable) Wiring the AFD to an addressable

panel using an auxiliary power supply for power:
Remove the Relay Wires from under the Power Terminals. Connect these
wires to the Addressable Module.

Figure 5. Wiring the AFD using 4 wires. (Aux. Power from Panel):
Remove the Relay Wires from the Power Terminals. Cut off the spade
lugs from the ends of the Relay Wires. Put wire nuts over ends of Relay
Wires as shown. Use Aux. Relay Terminals to make connection to panel
and next device as shown.

AUX. POWER
OUTPUT

INITIATING
LOOP

A B COM

POWER
TERMINALS

AUX RELAY
TERMINALS

RELAY
WIRES

FACP

EOL POWER
SUPERVISION
RELAY (SHOWN
ENERGIZED)
A77-716 12/24V

EOL

NOTE:

To comply with NFPA code, never put more than two wires in
a wire nut.

Relay wires and power terminal wiring must be contained within either a
common enclosure or enclosures within 6 meters (20 feet) of each other
with wiring inside conduit.

CAUTION

AUX.
POWER
OUTPUT

MODULE

SLC
LOOP

A B

CO

M

POWER
TERMINALS

AUX RELAY
TERMINALS

RELAY
WIRES

FACP

MODULE

A B

C

OM

POWER
TERMINALS

AUX RELAY
TERMINALS

RELAY
WIRES

NOTE: PLACE MODULE EOL
RESISTOR ACROSS RELAY
WIRES INSIDE AFD COVER.

NOTE: PLACE MODULE EOL
RESISTOR ACROSS RELAY
WIRES INSIDE AFD COVER.

AFD
ENCLOSURE

AFD
ENCLOSURE

EOL POWER
SUPERVISION
RELAY (SHOWN
ENERGIZED)
A77-716 12/24V