M500FP Firephone Control Module

INSTALLATION AND MAINTENANCE INSTRUCTIONS

BEFORE INSTALLINg
This information is included as a quick reference installation guide. If the
modules will be installed in an existing operational system, inform the op-
erator and local authority that the system will be temporarily out of service.
Disconnect power to the control panel before installing the modules.

NOTICE: This manual should be left with the owner/user of this equipment.
gENERAL DESCRIPTION
M500FP Firephone Control Modules are intended for use in intelligent, two-
wire systems, where the individual address of each module is selected using
the built-in rotary switches. This module is used to connect a remote fire-
fighter telephone to a centralized telephone console. A ringing sound is pro-
vided at each off-hook handset until it is connected to the console. Wiring to
individual telephone jacks and handsets is supervised, and status is reported
to the panel as NORMAL, TROUBLE, or TELEPHONE. The M500FP has two
pairs of output termination points available for fault-tolerant wiring, and in-
cludes a panel-controlled LED indicator.
COMPATIBILITy REqUIREMENTS
To ensure proper operation, this module shall be connected to Listed compat-
ible system control panels only.
MOUNTINg
This module mounts directly to 4″ square electrical boxes (see Figure 2A).
The box must have a minimum depth of 2

1

/

8

″. Flush mounted electrical boxes

(SMB500) are available.
WIRINg
NOTE: All wiring must conform to applicable local codes, ordinances and
regulations.
1. Install module wiring in accordance with the job drawings and appropri-

ate wiring diagrams (Figures 3-4).

2. Set the address on the module per job drawings.
3. Secure module to electrical box (supplied by installer), as shown in

Figure 2.

FIgURE 1. CONTROLS AND INDICATORS

FIgURE 2. MODULE MOUNTINg:

C1070-03

C1059-02

SPECIFICATIONS
Normal Operating Voltage:

15 to 32 VDC

Maximum Current Draw:

7.5mA (LED on)

Average Operating Current:

2.4mA (LED flashing)

SLC Wiring Resistance:

40 Ohms

Supervisory Wiring Resistance:

50 Ohms

Handset Offhook Resistance:

400 to 1,500 Ohms

External Supply Voltage (between Terminals T10 and T11)

Regulated 24VDC

Temperature Range:

32˚F to 120˚F (0˚C to 49˚C)

Humidity:

10% to 93% Non-condensing

Dimensions:

4.5” H x 4.275” W x 1.4”D (Mounts to a 4” square by 2

1

/

8

” deep box.)

Accessories:

SMB500 Electrical Box; CB500 Barrier