Assembly instructions

GB

Electrical connection

• The electrical connection must be carried out by a quali-

fied electrician who is authorised to carry out such work!

• Statutory regulations and the connection specifications issued

by the local power supply company must be strictly observed.

• When connecting the appliance it must be ensured that there

is a device which makes it possible to disconnect it from the
mains at all poles with a contact opening width of at least
3 mm. Line-protecting switches, fuses or contactors are
suitable cut-out devices.
When connecting and repairing the appliance disconnect it
from the electricity supply with one of these devices.

• The earth wire must be sufficiently long so that if the strain

relief fails, the live wires of the connecting cable are subjected
to tension before the earth wire.

• Any superfluous cable must be removed from the installation

area beneath the appliance.

• Make sure that the local mains voltage is the same as the

voltage on the rating label.

• Full protection against accidental contact must be ensured on

installation.

• Important! Incorrect connection may result in the power

electronics unit being destroyed.

No mains cable present in the factory
• To connect the appliance, unscrew the cover of the connection

socket on the underside of the appliance in order to be able to
access the terminal. After connecting the appliance, replace
the cover and secure the connection cable with the strain relief
clamp.

• The connection cable must be at least H05 RR-F.

Electrical connections: 5-pole connection

* Attention! Special power supply 220 - 240 V 3~ !

Electrical connections: 6-pole connection