Buffer Size and Segments

The Analyzer Settings tab has the Recording Buffer pane where you can set Number of 
Segments and the Segment Size. The defaults are one segment of 25MB. The total size 
used is automatically displayed for you. Setting multiple segments will allow to trigger on 
the first occurrence of the trigger condition, fill up the first segment, then automatically 
re‐arm the trigger and repeat the remaining number of segments specified. You can use 
the slider button or click the up or down arrow to change memory usage for recording 
trace data. (Minimum size of memory is 1MB. Maximum size of memory is dependent on 
the hardware.) (See Figure 2.1:   on page 34.) Enter an integer Num. of Segment, from 1 
to 32, then enter an integer Segment Size in kilobytes, up to the memory size in 
megabytes divided by the number of segments. The default 1. 

The New Project dialog opens with default settings to capture Everything on the bus and 
to Trigger On on Snapshot. (The analyzer captures everything immediately without 
triggering on anything in particular.)

Each time a trigger condition occurs, the system records a new segment. You can use a 
Snapshot or Pattern trigger, but not Manual Trigger. As the same trigger automatically 
repeats, the system makes the number of segments that you entered.

Note:

If the size of a data packet exceeds the buffer memory allocation, the project runs, but no data 

capture occurs. You must increase buffer memory size to a value greater than the packet size.

Trigger Position

You can set the trigger position in the captured buffer as a percentage of the segment 
size. Trigger point of 0% means the trigger point will be on the first packet in the buffer.

To upload segments automatically for display as the system creates them, do not select 
the checkbox.This defaults to 1, which defines the amount of data to capture before and 
after the triggering Event. You can change this percentage by dragging the slider.

In certain cases, when one port is recording traffic and filling up the memory much faster 
than another port, you might see traffic appearing only on one port for a while, and the 
other port's traffic will only appear later. This occurs as a function of the trigger position, 
and is normal, expected behavior of the analyzer.

To upload segments manually in the Segment Manager, select the Use upload manager 
(no automatic upload)
 checkbox. To upload segments automatically for display as the 
system creates them, do not select the checkbox.

Auto Run

To repeat the current capture and trigger setup automatically, check the Auto Run 
checkbox and enter the number of times in the Number of Run text box. The capture and 
trigger repeat automatically for the specified number of times, and the results are saved 
in consecutively numbered Trace.scs files. Each one will use the same settings as 
specified, and will create sequentially named traces. This is identical to pressing the 
record button several times in a row. 