Teledyne LeCroy CPCI-H110 User Manual

Page 6

Advertising
background image

6

SPECIFICATIONS

Bus

CPCI-H110, CompactPCI H110, 5V or 3.3V

Extender

Voltage Requirements:

+5V, +12V & -12V @ 50 mA at no load.

UUT

Input Voltage Source:

+5V, +/-12 V

From the system bus or the external input, configurable by jumpers per

voltage.

+3.3V

From the system bus, on board regulator, or the external input, configurable

by jumper.

Output Ratings:

+5V

Jumper selectable to 10 Amp or 2 Amp limit.

+3.3V

3.0 Amp using on board regulator, or 8A using external input voltage and bus

voltage.

+/- 12V

1 Amp.

Output Voltage Drop:

50 mV drop for every 1 Amp drawn for +5V, +3.3V and +VIO.

80 mV drop for every 100 mA drawn for -12V.

50 mV drop for every 100 mA drawn for +12V.

Outputs:

J3.1

Ground

J3.2

+5V current measurement, One Volt represents one Amp.

J3.3

+12V current measurement, One Volt represents one Amp.

J3.4

+3.3V current measurement, One Volt represents one Amp.

JT1, JT2

All CompactPCI H110 signals.

JT3, JT4

Breakout points for monitoring CompactPCI Signals

Mechanical Dimensions:

Height

8.00 inches (203 mm)

Length

9.186 inches (233.32 mm)

Advertising