Error trigger setup, Flexray decoding, Decode and decode setup – Teledyne LeCroy FlexRay Trigger, Decode and Physical Layer Test User Manual

Page 12

Advertising
background image

Error Trigger Setup

This set of checkboxes are shown if Error is selected as
the trigger type. The errors are broken in to 2 categories,
Protocol Errors and CRC Errors.

Protocol Errors:

• Frame Start Sequence (FSS)

• Byte Start Sequence (BSS)

• Frame End Sequence (FES)

CRC Errors:

• Header

CRC

• Payload

CRC

• The correct channel must be selected when triggering

on CRC errors

• Check or uncheck each one, as desired, to include or

not include that specific type of error in the trigger.

• For convenience Select and Deselect All buttons are

available when using Error triggering.

• Detailed description of the Error Triggers is found in

Appendix C.


FlexRay Decoding

FlexRay decoding tools are easily accessible in a variety of ways. The D, TD and TDP options add a new set of
dialogs for Decode setup. These dialogs are shared by all the low-speed serial protocols that LeCroy offers, so all
serial trigger and serial decoding selections are grouped in a common selection with nearly identical selection and
setup. These dialogs are conveniently accessed with just one or two touches of the screen.

Decode and Decode Setup

These dialogs provide the ability to set the oscilloscope up for FlexRay decoding, with display of the protocol data
overlaid on the signal. They also allow quick and easy access to oscilloscope zooming, searching, table display,
and table export.

The serial decode and decode setup dialogs are accessed in the following ways:

1. Touch

Analysis

Æ Serial Decode from the menu bar. The Serial

Decode Summary dialog is shown which provides access to
Decode Setup.

2. Touch

the

Channel or Memory Descriptor Box to open the

respective dialog box, and touch the Decode button on the bottom
toolbar.

12

FlexRay-TDP-OM-E Rev A

Advertising