QPHY-BroadR-Reach Software Option

Figure 12 – Transmitter Output Droop

Shown on this screen:

• F1 is the input differential signal which the measurements will be performed on

In the measurement section:

• T1 is the zero crossing time of the positive edge and t2 is the zero crossing time of the negative

edge.

• Vpk+ is the maximum value of input signal and Vpk- is the minimum value of input signal.
• Vdrooped+ is the value 500 ns after the maximum value and Vdrooped- is the value 500 ns after the

minimum value.

• Droop+ is the droop calculated on the +1 symbol and Droop- is the droop calculated on the -1

symbol.

• Q7 compares Droop+ to 26.9% and Q8 compares the Droop- to 26.9%.

Figure 13 – Transmitter Output Droop Test Results

922533 Rev B