ELECTRICAL

Loop Resistance

less than 300

(talk mode)

Monitor Impedance

greater than 100k

ROTARY DIAL OUTPUT
Pulsing Rate

100pps +/-0.8%

Make Rate

33 +/-3%

Minimum Pulse

600ms over

DTMF OUTPUT
Frequency Deviation

+/-1.8%

Level Deviation

High -8dBm, Low -6dBm +/-0.8%

Return Loss

2dBm

Redial

32 digits

Insulation Resistance

0.1- 10M

(DC 180V)

Power Source

DC 9V

INSULATION RESISTANCE & CAPACITY MEASUREMENT

1. Connect the alligator clips to L1 and L2 of subscriber side.
2. Push the METER CALL (10) button.
3. The insulation resistance will be displayed on the 'Mega Ohm meter,

when the METER CALL button is pressed.

Generally, there are two conditions:

Normal condition (good insulation between L1 and L2)
The meter scale goes to 0.2

generally and then back. This is caused

by the capacity of the connected subscriber's telephone or the line and
terminal.

Abnormal condition (bad insulation between L1 and L2)
The meter scale goes up to a low value (below 1M

) and stays there.

This indicates a faulty circuit on L1 and L2.

Note - The meter will not move if the line is an open circuit.

BATTERY CHECK

Indicates if 9-volt battery requires replacement.
1. Connect the two alligator leads together.
2. Press the METER CALL (10) button. A good battery is indicated if the

needle is in the BT section of the meter. If the needle is below, the bat-
tery should be replaced.