7.0 Troubleshooting chart

You have chosen the best quality and deserve the best performance. To speed returning the machine to
service, check the following before contacting the nearest ALTO service organization:

Fault

Cause

Correction

Machine will not start

Fuse/breaker blown

Replace/Reset

Cord not connected

Connect power cord

Defective extension cord

Try without extension cord

Defective receptacle

Try another receptacle

Machine stops

Excess-current cut-out on

Allow the button system to cool. Check the

unintentionally

start/stop button activated

following items 1-3 and then restart the

-restart possible

machine.

after 60 sec.

1)

Wrong voltage

Check that the supply voltage
corresponds to the data plate (see sec. 1.1)

2)

Extension cords too

Remove extension cord or use

small

correct cord size spec (see sec. 2.1)

3)

Nozzle partly blocked

Clear the nozzle (see sec. 6.3)

Fuses blow

Check that the installation provides the am
pere required by the machine. Check for
anything else loading the circuit (ie. Heater,
coffee pot)

Pressure fluctuating

Water supply too low

Check the water supply (min. 3 gpm).

and pulsating

Avoid long, thin hoses (min. ½").

Inlet water screen clogged

Clean the screen (see sec. 6.1)

Pressure varies from

Nozzle partly blocked

Clear the nozzle (see sec. 6.3)

max. to min.

High pressure hoses too

Detach high pressure extension hoses

long

and retry. Extension hose max. 33 ft.

Scale deposits in burner

Descale coil (see sec. 6.2)

No working pressure

Nozzle clogged

Clear the nozzle (see sec. 6.3)

No inlet water

Check inlet water

Hoses/spray lance frozen

Let them thaw

The burner does not ignite

Safety thermal breaker

Serious fault in the burner/control system.

activated

Send for an ALTO service technician.
(The machine can still be used in the cold
water mode.)

Fuel tank empty

Fill with at least 2 gal.
The machine must not run without fuel !

Fuel filter blocked

Clean or replace the filter (see sec. 6.1)

Heavy

black smoke

Burner air or fuel improper

Obtain service.

Insufficient heating

Scale deposits in coil

Descale coil (see sec. 6.2)

Burner out of adjustment

Obtain service.

Should malfunctions occur than those mentioned above, please contact the nearest ALTO service organi-
zation. If you don’t know how to contact your selling or nearest distributor, call

ALTO Technical Support:

Phone: 1.800.331.7691