Automatic Power Off
The PRO-Chek CO automatically turns off after 20 minutes.
When starting up after an automatic shut down, the concentration
reading the meter was displaying when shut down will fl ash for 5
seconds before the meter returns to reading the concentration in
real time.

Specifi cations
Usage

Indoor or outdoor

Pollution degree

2

Humidity

90% RH NC max

Overvoltage category

2

Battery

One 9 volt alkaline

Altitude

2000

m

Battery life

200 hours

Weight

9.0 oz (250 g)

Operating temperature

32 to 110 °F (0 to 43 °C)

Storage temperature

14 to 122 °F (-10 to 50 °C)

Concentration range

0 to 999 ppm CO

Accuracy

1 ppm ±3% of reading

Warranty and Liability
Your PRO-Chek CO Carbon Monoxide Meter is of the fi nest
design and craftsmanship. As such, Tracer Products warrants that
when delivered it will be free from defects in manufacture.

Tracer Products’ obligation under this warranty is limited to
repairing or replacing, at the option of Tracer Products, any
part(s) of the product which, if properly installed, used and
maintained, proves upon factory examination to have been
defective in materials or workmanship within two years from the
date of delivery.