Features – Tracer TP-9367 Marksman II AM12002 User Manual

Page 4

Advertising
background image

4

FEATURES

The Marksman

II Ultrasonic Diagnostic Tool converts and amplifies

inaudible ultrasonic sound into audible “natural” sound by

employing technologically advanced circuitry. It operates on the

principle of detecting high frequency ultrasonic waves, which are

created by friction from all moving parts, whether solid, liquid or

gaseous. These “sounds” reside far above the range of the human

ear and tend to be highly directional.

This directional aspect of ultrasonic waves allows one to isolate a

suspect signature sound from other background noises and detect its

exact location. This sound analysis can be used for efficiently

investigating the following areas of repair and preventive maintenance

in the following transportation and industrial applications:

1)

Air leaks

Both vacuum and compressed air leaks create an energy

packet or wave front which can result in an ultrasonic emission

with a differential of 5 psi from a 12 inch (30.5 cm) distance,

and/or a hole down to 0.004 inches (0.1 mm) in diameter.

2)

A/C refrigerant leaks (for most types of refrigerant)

3)

Gas and liquid turbulence

Turbulence associated with steam trap and internal valve

leaks, cavitation, and blockages in liquid and air/gas lines.

4)

Electrical discharge

Electrical discharge associated with insulation breakdown,

tracking, corona and arcing.

5)

Diagnosing solenoid operations

6)

Mechanical wear

State of mechanical wear in bearing and race assemblies,

shafts and gears (also indicating the state of lubrication).