Iq23x series controllers, Installation instructions - node part 1 – TREND IQ23x User Manual

Page 29

Advertising
background image

8

IQ23x Series Controllers Installation Instructions TG200539 Issue 1/A 26/3/02

8 - 1

Installation Instructions - Node Part 1

IQ23x

Series Controllers

R X

T X

O K

1

2

8

4

16

32

64

1K

2

9K

6

19

K

2

A D D R E S S

B A U D

J48

J47

R X

T X

O K

1

2

8

4

16

32

64

1K

2

9K

6

19

K

2

A D D R E S S

B A U D

SHEET 8: Installation Instructions - Node Part 1

IQ131 internal
CNC board

2

8 Installing an auxiliary internal node board from a replaced controller - part 1

The IQ131 auxiliary internal CNC
node board is replaced by the
IQ233 firmware node, so the CNC
board can be discarded.

IQ1xx Supervisor CNC board

3

If an auxiliary internal CNC board was fitted to allow
a local supervisor or NDP to communicate over the

network, this can now be achieved by setting the local
supervisor port address in the range 1, 4 to 119 (excluding
address 10, see Sheet 3, Section 3.2) and the CNC board
can be discarded.

O

I

A

D

D P

C

B

R X

T X

O K

1

2

8

4

16

32

64

1K

2

9K

6

19

K

2

A D D R E S S

B A U D

4

Switch Off

O

I

Isolate I/O

5

WARNING: The connecting leads

may be connected to
supplies. Isolate before
touching.

Open Panel

6

1 2 3 4 5 6 7 8 9 1 0

R X

T X

O K

A D D R E S S B A U D

S W 4

A

D

D P

C

B

J 1 6

D e v B

J 1 5

D e v A

Remove Cover

7

A

D

D P

C

B

R X

T X

O K

1

2

8

4

16

32

64

1K

2

9K

6

19

K

2

A D D R E S S

B A U D

R X

T X

O K

1

2

8

4

16

32

64

1K

2

9K

6

19

K

2

A D D R E S S

B A U D

remove 5 screws

Remove Network Links

8

Connect Local Network Cable

9

J48

J47

pull off links

J48

J47

Not ANC, AND, MNC, TMN if on internetwork.
Not INC2 if used as internetwork repeater (dumb/normal =
normal, address >= 100).

polarized
connector

CABLE/EJ103086

KIT/NODE/IQ23x

1

All the parts required to install
a node into the IQ23x are
included in KIT/NODE/IQ23x.

WARNING:

Opening the panel

may expose
dangerous voltages.

417-IEC-5036

R X

T X

O K

1

2

8

4

16

32

64

1K

2

9K

6

19

K

2

A D D R E S S

B A U D

10

CAUTION: This unit contains static sensitive devices.

Suitable anti-static precautions should be
taken throughout this operation to prevent
damage to the unit.

BS EN100115/1 Basic Specification: protection of
electrostatic sensitive devices.

Install Support Pillar

Select Board Plate

11

If the node board is of
TMN type (CNC2,

PNC2, INC2, TMN) then select
the TMN type board plate, else
(CNC, PNC. INC, ANC, AND,
ENC, XN28, XNC+, MNC,
LINC) select the pre-TMN type
board plate.