T/tfr-4 installation instructions, Installation disposal, Trend control systems limited – TREND T_TFR-4 User Manual

Page 2: Trend control systems usa, Weee directive, Mount sensor, Wire to controller, Set up iq sensor types, Test system, If iq

Advertising
background image

2

T/TFR-4 Temperature Sensor Installation Instructions TG200660 Issue 1/D 19/03/07

T/TFR-4

Installation Instructions

Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route
du Bois 37,Switzerland by its Authorized Representative.

Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content
hereof without obligation to notify any person of such revisions or changes.

Trend Control Systems Limited

P.O. Box 34, Horsham, West Sussex, RH12 2YF, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trend-controls.com

Trend Control Systems USA

6670 185th Avenue NE, Redmond, Washington 98052, USA. Tel: (425)897-3900, Fax: (425)869-8445 www.trend-controls.com

WEEE Directive :

At the end of their useful life the packaging
and product should be disposed of by a
suitable recycling centre.

Do not dispose of with normal household waste.
Do not burn.

Mount Sensor

3

Installation

Disposal

Wire to controller

4

grommet

IQ1x, IQ2xx

C

IN

Analogue
input channel
linked for
thermistor
(T)

0 (0V)

N (in)

+ (24V)

IQ3

Set up IQ Sensor types

5

Test System

6

tYpe Sensor digI/P Driver Function loGic Loop scHedule seQnc Analog

digBit Knob sWitch Time Zone Oss User addRess intcoN calarM reView Plot

calEndar

= ?

Thermistor (-10 to +50 °C, 14 to 122 °F)

Yn<CR>
TYPE n
:
=?
S=5 (characterise)
Y=, E=, U=, L=, P=,
I1 to I6=, O1 to O6=
X <CR>

It is recommended to use SET (software tool) for the setting of sensor type modules. For all IQ2 series controllers with
firmware version 2.1 or greater, or IQ3 series controllers, one of the the following SET Unique Sensor References should
be used:

Thermistor TFR-4 (°C)
Thermistor TFR-4 F (°F)

Alternatively enter scaling manually as defined in the table below.
For all other IQ controllers see Sensor Scaling Reference Card TB100521A.

s

t

i

n

U

C

°

F

°

Y

e

p

y

t

t

u

p

n

I

)

s

t

l

o

v

r

o

t

s

i

m

r

e

h

t

(

1

E

t

n

e

n

o

p

x

E

3

U

r

e

p

p

U

0

5

2

2

1

L

r

e

w

o

L

0

1

-

4

1

P

s

t

n

i

o

P

6

x

x

I

x

O

1

1

4

6

.

2

0

5

2

2

1

2

7

4

.

3

0

4

4

0

1

3

6

4

.

4

0

3

6

8

4

3

6

6

.

6

0

1

0

5

5

8

6

6

.

7

0

2

3

6

2

0

1

.

8

5

-

3

2

IQ

If IQ

Δ T

Advertising