Cart-23 – Vestil CART-23 & -24, ALL MODELS User Manual

Page 10

Advertising
background image

11/13/02

08/17/05

CART manual, power unit operation.doc

10 of 12

T

ROUBLESHOOTING

G

UIDE

--

CART-23,

-24

Warning: Before performing any task, always remove any load and lower the platform fully to the floor.

* Check the DC notes page for troubleshooting other problems specific to battery-powered units.
Consult the factory for problems at time of installation, or for any problems not addressed below.

Problem: Possible

cause(s): Action:

Power unit doesn’t run when

“UP” button is pressed (DC

units).


Upper-travel limit switch is

engaged or bad.

Bad motor relay coil.
Battery voltage low.


Control cable’s connector is
loose.

Test with meter; replace if bad.

Test with meter; replace if bad.
If LED on motor relay is not on,

check battery voltage with
meter.
Check quick-connect plug.

Motor runs, platform doesn’t

move (DC units).

Pump has gone bad.

Consult factory.

Motor hums or pump squeals,

but the platform does not

move, or the platform moves
only slowly (DC units).

Platform overloaded.

Pressure relief opening at full

pressure.

Verify that the load doesn’t

exceed the table’s capacity.

Check for structural damage or

binding of the scissor legs,

etc.
Check for platform overload

condition.

Spongy or jerky platform

movement.

Excessive air in the hydraulic

cylinders.

Bleed air per procedure

described in this manual.

Platform won’t lower.

Solenoid coil is bad or connector

is loose (DC units).
Solenoid valve or suction hose

screen plugged (DC units).
Physical blockage of the

structure.

Check with meter. Check quick-

connect plug.

Remove and inspect. Clean per

instructions in this manual.

Inspect for foreign material or

objects that might block the
leg set or its rollers.

Platform lowers too slowly.

Pinched hose.

Flow control spool sticking.


Velocity fuse locking (platform

only slowly creeps down).

Check pressure, supply, and

return hoses for kinks.

Remove plug from FC port; push

on flow spool to ensure it is

fully pressed into the cavity.

Same as for jerky platform

movement.

Platform raises, then drifts

down.

Contamination holding open the

lowering valve or the check
valve.

Remove and inspect. Clean per

instructions in this manual.

Advertising