Mounting and wiring – VIAIR 100C User Manual

Page 3

Advertising
background image

100C Air Compressor Kit

MOUNTING AND WIRING

1. Disconnect ground cable from vehicle’s battery.

2. Temporarily position the air compressor in the location where it will be mounted.

3. Route ground wire to the negative post of the battery or to an appropriate grounding point

and cut ground wire to length as needed.

4. Mount air compressor with the four sets of bolts, nuts, washers, and locking washers provided.

(See Fig. 2 for Mounting Instructions)

5. Refer to Remote Air Filter Installation Instruction included in the Remote Inlet Air Filter Pack for

installation of Remote Inlet Air Filter.

6. This air compressor may be equipped with a heat resistant leader hose. (Not applicable to P/Ns

10014 or 10016) This leader hose is designed to prolong the life of your air line. Do not remove

this leader hose from air compressor.

7. Please note, the leader hose that came with your compressor may have a built-in inline check

valve installed. Do not remove inline check valve from leader hose if so equipped.

8. If equipped, select a proper location to mount leader hose with hose bracket provided. Avoid

locations where leader hose may become tangled with wires and other hoses.

9. To mount hose bracket, drill hole with 3/16” drill bit and push self–anchoring hose bracket pin

into hole. Route leader hose through hose bracket and secure hose by pressing bracket clamp

into locked position.

10. To remove hose from the hose bracket, simply press down on the hose clamp release tab to

release bracket clamp. (Fig. 3)

11. Connect compressor positive lead wire to one of the leads of your pressure switch.

12. Make sure that your compressor setup is properly fused. For appropriate fuse size, refer to amp

draw of compressor in the Specifications section of this manual.

13. Always locate fuse as close as possible to power source.

14. Before connecting to power source, re-check to make sure that all connections

are properly connected.

15. Connect and test compressor system by running the compressor for a short time to build up

pressure in your air tank.

16. Once air pressure reaches preset cut out pressure of your pressure switch, the compressor

will shut off. Inspect all air line connections for leaks with soap and water solution. If a leak

is detected, the air line may not be cut squarely or pushed all the way in. Tighten connections

if needed.

(Fig. 1) Standard 100C Air Compressor Kit Installation Parts List:

A. Hose Bracket (1pc) (10010)

B. Mounting Bolts (4pcs)

C. Flat Washers (8pcs)

D. Locking Washers (4pcs)

E. Nuts (4pcs)

F. 1/4” NPT F x 1/4” Barbed Fitting (1pc) (10010)

G. 1/4” Air Line (1pc) (10010)

H. Air Line Clips (3pcs) (10010)

I. Screws (3pcs) (10010)

J. Remote Inlet Air Filter with Filter Element (1pc) (10010)

(Fig. 2) Compressor

Mounting Hardware

B. Mounting Bolt

C. Flat Washer

D. Locking Washer

E. Nut

K. Vibration Isolator

USER MANUAL

B

A

C D E

F

H

I

J

(Fig. 3) Leader Hose Bracket

L. Hose Clamp

M. Clamp Release Tab

N. Self Anchoring Pin

B
C

C

D
E

K

L
M

N

G

Advertising