Troubleshooting guide – VIAIR 400P-Auto User Manual

Page 7

Advertising
background image

TROUBLESHOOTING GUIDE:

Compressor will not run

1. No power, or power switch

in OFF position

2. Blown fuse
3. Motor overheats

1. Make sure compressor

switch is ON

2. Disconnect compressor

from power source, replace
fuse. (Refer to Specifications
section for correct
fuse amperage)

3. Let compressor cool off for

about 30 minutes to allow
thermal overload switch to reset.

Thermal overload
protector cuts out
repeatedly

1. Lack of proper ventilation or

ambient temperature is too high

2. Compressor valves failed

1. Move compressor to well

ventilated area, or area with
lower ambient temperature

2. Replace compressor

Excessive knocking
or rattling

1. Worn bearing on eccentric or

motor shaft

2. Cylinder or piston ring is worn

1. Service or replace compressor

Compressor air flow lower
than normal, or cannot
pump to higher pressures

1. Worn piston ring or inlet valve

1. Service or replace compressor

PROBLEM:

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

400P AUTOMATIC PORTABLE COMPRESSOR

USER MANUAL