Troubleshooting guide – VIAIR 150 PSI High-Flow User Manual

Page 8

Advertising
background image

Tank pr

essur

e dr
ops when

compr

essor(s)

shut

of

f

1. Loose drain cock

2.

Check

valve

leaking

3. Loose connections

1. Tighten drain cock

2.

Replace

check

valve

or

compr

essor(s)

3.

Check

all

connections

with
soap

and

water solution and tighten

Compr

essor

runs

continuously

and

air

flow
lower

than

normal

1.

Excessive

air

usage

2. Loose connections

3.

W

or

n piston

ring
or

inlet
valve.

4.

Clogged

air

filter

element

1. Decr

ease air usage

2.

Check

all

connections

wit
soap

and

water solution and tighten.

3.

Repair

or

replace

compr

essor

4.

Replace

air

filter

element

Compr

essor

runs

continuously

causing

safety

valve

(if

equipped)

to

open

1.

Bad
pr

essur

e switch

2.

Defective

safety

valve

1.

Replace

pr

essur

e switch

2.

Replace

safety

valve

PROBLEM:

POSSIBLE

CAUSE(S)

CORRECTIVE

ACTION

TROUBLESHOOTING GUIDE:

Advertising