QUARTER DUTY ONBOARD AIR SYSTEM

2.0 GALLON AIR TANK & PLUMBING

Your 2.0 gallon air tank comes with five 1/4” NPT port openings to allow installation in many configurations on

your vehicle. To insure safe and trouble-free use of your air tank, we strongly recommend that you install the

supplied drain cock and a safety pressure relief valve. (See Figure 1)

Tank Fittings:

Install the supplied compression fittings and/or quick connect fitting for the air tank in areas where they are

most appropriate for your installation using thread sealant or Teflon tape. Make sure that the safety valve is

installed in the top most position on the tank, and that the drain cock is installed in the lowest position on the

tank if the tank is to be installed in any other position than upright on the tank’s mounting legs. Be sure that all

fittings are accessible later in the installation process since you will have to plumb air lines to each fitting as

needed to utilize the air tank.

IMPORTANT:

- Tank is rated for 150 PSI maximum working pressure.

- Tank is NOT to be used as a breathing device.

- Bleed pressure from tank before servicing or adding attachments.

- Use only attachments or tools rated for 150 PSI working pressure or less.

CAUTION! DO NOT PRESSURIZE YOUR TANK UNTIL YOU HAVE INSTALLED

ALL NECESSARY PORT FITTINGS AND ACCESSORIES.

- Apply sealant to threads of fittings prior to assembly and tighten each part with a wrench.

- Do not over tighten if your port fittings are made from brass, since brass threads can be stripped.

- Always release air from tank before servicing.

WARNING: FAILURE TO DRAIN TANK AND REMOVE CONDENSATION

WILL CAUSE TANK TO RUST PREMATURELY.

- To remove accumulated condensation inside the tank, bleed pressure from tank until pressure is

approximately 5-20 PSI using drain cock

- If drain cock valve is plugged, release all air pressure from tank, remove drain valve and clean, then reinstall.

IMPORTANT: Please observe air tank’s Date of Manufacture (stamped on tank leg).

Replace air tank 2 to 5 years from date air tank was first used, or use the date of manufacture as reference.

Adhering to air tank draining guidelines will prolong the life of your air tank.

PLEASE NOTE: RUSTED TANKS CAN FAIL CAUSING EXPLOSIONS OR FATAL INJURIES.

Discard tank immediately if tank is rusted.

SAFETY VALVE: When using a safety pressure relief valve, point the safety pressure relief valve away

from your body when releasing air. Use the pull ring on the safety relief valve to vent pressure from the

tank before servicing.

P/N 10002

OBA PLUMBING DIAGRAM

15 Edelman

Irvine, CA 92618

949-585-0011

www.viaircorp.com

2.0

Gallon

Tank

Drain

Cock

Pressure

Switch

Safety

Valve

Compression

Fitting

Leader Hose

From Compressor

Rev.1

Plumbing Diagram:

(Figure 1)