Wiring guidelines for the cv7 panels, Preparing captive wires, Using the psn netlinx connector for power – AMX NXD-CV7 User Manual

Page 49

Advertising
background image

Installation

41

7" Modero Widescreen Touch Panels

11. Reconnect the terminal RJ-45 audio/video, Ethernet, and USB wiring to their respective

terminal locations on either the NXA-AVB/ETHERNET Breakout Box, Ethernet port, or

NetLinx Master.

12. Reconnect the terminal power connector on the PSN and apply power.

Wiring Guidelines for the CV7 Panels

CV7 panels require 12 VDC power from a PSN NetLinx Power Supply to operate properly. The

panels connect to the power supply via a 2-pin 3.5 mm mini-Phoenix connector.

Preparing captive wires

You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.

1.

Strip 0.25 inch (6.35 mm) of insulation off all wires.

2.

Insert each wire into the appropriate opening on the connector (according to the wiring

diagrams and connector types described in this section).

3.

Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively;

doing so may strip the threads and damage the connector.

Using the PSN NetLinx connector for power

The PWR and GND cable from the NetLinx Power Supply (PSN4.4 or PSN6.5) must be connected

to the corresponding location on the 2-pin 3.5 mm mini-Phoenix connector (FIG. 40).

1.

Insert the PWR and GND wires on the terminal end of the PSN 2-pin 3.5 mm mini-Phoenix

cable. Match the wiring locations of the +/- on both the power supply and the terminal

connector.

2.

Tighten the clamp to secure the two wires. Do not tighten the screws excessively; doing so may

strip the threads and damage the connector.

3.

Verify the connection of the 2-pin 3.5 mm mini-Phoenix to the power supply.

These units should only have one source of incoming power. Using more than one
source of power to the touch panel can result in damage to the internal components
and a possible burn out.
Apply power to the panels only after installation is complete.

Never pre-tin wires for compression-type connections.

FIG. 40 NetLinx power connector wiring diagram

PWR +

GND -

To the Touch Panel

NetLinx Power Supply