Installation

43

7" Modero Widescreen Touch Panels

Connecting and Using USB Input Devices

The CV7 panel can have up to two USB-capable input devices connected for use on its different

firmware and TPD4 panel pages. These input devices can consist of a keyboard or mouse.

1.

Insert the input device USB connectors into the appropriate USB connector on the panel.

2.

Press the on-screen Reboot button from the Protected Setup page to save any changes and

restart the panel.

3.

After the panel splash-screen disappears:

If a USB mouse has been connected, a mouse cursor appears on the panel screen and its

location corresponds to the mouse cursor position sent by the external USB mouse.

If a USB keyboard has been connected, only on-screen keyboards and keypads will

reflect any external keystrokes sent from the external USB keyboard.

FIG. 42 RJ-45 wiring diagram

USB-connected input devices are not detected and recognized by the panel until
power is cycled to the unit.
A mini-USB connection is only detected after it is installed onto an active
panel. Connection to a previously powered panel, allows the PC to detect the
panel and assign an appropriate USB driver.