Configuring Communication

70

7" Modero Widescreen Touch Panels

Master Connection section - NetLinx Master Ethernet IP Address - Listen Mode

In this mode, you must add the Modero panel IP Address into the URL List of the Master (using

NetLinx Studio). This mode sets the Modero panel to "listen" for broadcasts from the Master (using

the panel IP from its URL list).

1.

Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP

Address from the IP Settings of the System Connection page.

The DHCP/Static field (in the IP Settings section of the System Connection page) must

be set to DHCP to get Dynamic IP information for the panel.

Press the on-screen Reboot (from the Protected Setup page) to both save any changes and

restart the panel.

After power-up, press the grey Front Setup Access button for 3 seconds to access the

Setup page.

Navigate to the Setup > Protected Setup > System Connection page and note the newly

obtained Dynamic IP Address information from the IP Settings section. This information

is then entered into the URL List for the connected NetLinx Master.

2.

Toggle the Type field until Ethernet is selected (from the Master Connection section of the

System Connection page).

3.

Press the Mode field (to set the connection Mode) until the choice cycles to the word Listen.

The System Number and Master IP/URL fields are then greyed-out.

4.

Enter a username and password (into their respective fields) if the target Master has been

previously secured.

5.

Select the OnLine Tree tab from the Workspace window.

6.

Select Diagnostics > URL Listing from the Main menu (FIG. 64).

7.

Enter the System and Device number for the specific Master associated with your panel (as

seen in the OnLine Tree tab).

8.

Click Add and enter the IP Address of the Modero touch panel into the Add URL dialog.

9.

Click OK to enter your IP Address and add it to the list.

10. Click Done once you are finished adding your panel information to the list.

FIG. 64 URL List dialog

System Address

reflects the value

set in the Device

Addressing tab

Used to obtain an

existing URL

Used to set the

URL List

List from Master