Specifications

Input

208-575VAC, 50/60 Hz.

Output

Range 30-100 VDC (adjustable). 0.5
amps

Fusing
(Optional)

1 amp, 250 V fast-blow

Ambient
Temperature 0 to 122 F, (-18 to 50)C

Switching

Supplied by Customer

Cycle Rate Consult Warner Electric’s Master

Catalog, form no. P-1000, for energy
dissipation of your application.

Set-Up

The recommended settings for
Electro module Fail Safe Motor
Brakes are as follows.

To insure optimum release, it is factory set to
90VDC. Adjust the potentiometer on the control to
the required brake coil voltage as measured with a
voltmeter. The recommended voltage listed below
is based on nominal line voltage.

Model Voltage

UM - 50

70-100 volts DC

UM - 100

70-100 volts DC

UM - 180

90 volts DC

UM - 210

70-100 volts DC

UM - 215

70-100 volts DC

Reorder Information

2

Warner Electric • 800-825-9050

819-0501

Failure to follow these

instructions may result in product damage,
equipment damage, and serious or fatal injury
to personnel.

Introduction

The Warner Electric CBC-160MV is a family of
clutch/brake controls conveniently built into the
conduit box cover of the Elecctro Module line of
electromagnetic clutches and brakes. The CBC-
160MV control is a single channel device, that is
adjustable for precise operation of the brake, with
flexible adjustable for precise operation of the
brake, with flexible voltage input from 208 to 575
VAC. This control is designed for operation with
Warner Electric’s permanent Magnet 90VDC Fail
Safe Motor Brakes. It may also be used with any
Warner Electric 90VDC clutch/brake.