Warner Electric MCS-805 User Manual

Page 3

Advertising
background image

3

Warner Electric • 800-234-3369

P-239-31

Specifications:

Input power:
• MCS-805-1 120/230VAC ± 10%,

50/60Hz, single phase.

• MCS-805-2 120/230VAC ± 10%,

50/60Hz, single phase

Output:

MCS-805-1

35-75VDC, 0.40 amps

MCS-805-2

35-75VDC, 0.40 amps

Switching inputs:
(external to control, supplied by customer)
• DC switching: single pole, single throw.

Minimum contact rating 1 amp, 120 VDC.

• AC switching: single pole, single throw.

Minimum contact rating 1 amp, 120 VAC.

Ambient temperatures:

-20° to 150°F (-29° to 65°C)

Circuit protection: (fusing)

3/4 Amps, 250V Slow Blow, 3AG

Adjustments:

Release band adjustment (via internal poten-
tiometer)
MCS-805-2 only: Torque adjust (via external
potentiometer)

Wiring Entrance:

Two 7/8" diameter conduit entrance holes
located on the bottom and on the top of the
control chassis.

Reorder Information

Model

Part No.

MCS-805-1

6090-448-006

MCS-805-2

6090-448-007

Mounting

Any vertical, horizontal, or angled surface is suit-
able for mounting the MCS-805-1 or MCS-805-
2. Follow these procedures to mount your con-
trol:

a. Remove the front cover by removing the top

retaining screws.

b. Set the control on the mounting surface and

mark for the four mounting holes in accor-
dance with dimensions.

c. Install and tighten the four screws.

The control is now ready to be wired.

To avoid injury (or even death),

always make certain all power is off before
attempting to install this control or any elec-
trical equipment. Do not touch the board if
power is applied.