5. Continue to slowly increase the applied

voltage until the armature re-engages the
magnet. If the maximum voltage available
from the supply does not cause the armature
to re-engage, the armature should be
manually assisted into engagement.
Note: If armature needs to be manually
assisted, armature should be pressed on
back side to make contact with friction face
of magnet.

6. With the armature re-engaged, slowly reduce

the applied voltage until the armature
disengages from the magnet. Note and
record the applied voltage at this point.

7. The optimum release point for the brake is

half-way between the two recorded voltage
readings. Adjust the supply to this optimum
release voltage.
Note: The above procedure should be done
by visually watching the armature move and
may be repeated if necessary from Step 1
through Step 7.

If any problems should occur during
adjustments or application questions arise,
please contact Technical Support at 1-800-825-
9050 Monday through Friday 7:30 a.m. - 4:30
p.m. central time.