819-0368

Electrical Data

Unit Size

Voltage

Resistance

Amperes

Watts

Torque Build Up Torque Decay

[ohms @ 75° F (25°C)] [@ 75° F (25°C)] [@ 75° F (25°C)]

(msec)

(msec)

0.3

24

35.6

.674

16.2

78

6

0.6

24

21.1

1.14

27.4

84

9

1.2

24

20.6

1.16

28.0

147

16

2.5

24

15.8

1.52

36.5

175

21

5

24

8.80

2.74

65.7

271

28

10

24

9.00

2.68

64.2

448

43

20

24

7.20

3.34

80.3

536

66

40

24

5.10

4.66

112

680

100

80

24

4.30

5.57

134

1310

300

Note: Build up time equals time for torque to build to approximately 63.2% of steady state value
after a step change in voltage. Decay time equals time for current to drop to approximately 36.8%
of steady state value after a voltage change.

Fan Motor Data (PTB-BL3 Brake only)

Size

Voltage

Wattage

(single phase 60 hertz)

2.5

115 VAC

20

5

115 VAC

38

10

115 VAC

38

20

115 VAC

38

Thermal Switch Data (PTB-BL3 Brake
only)

Type:

Normally Closed

Current Rating:

24 VAC

18 A

115 VAC

18 A

230 VAC

13 A

Advertising