Torque vs. current curve (typical) type: ptb-2.5bl, Torque vs. current curve (typical) type: ptb-5bl, Torque vs. current curve (typical) type: ptb-10bl – Warner Electric POC, PHC-R, PMC-A3, POB, PRB and PTB-BL3 User Manual
Page 11: Torque vs. current curve (typical) type: ptb-20bl
11
Warner Electric • 800-825-9050
819-0452
Torque (kgfm) = 0.1383 X Torque (lb.ft.)
Torque vs. Current Curve (Typical)
Type: PTB-2.5BL
(kgfm)
(lb. ft.)
4.0
1.0
0
0.2
0.4
0.6
1.6
10.8
14.5
18.1
21.7
28.9
Rated
Current
1.25
Amp
Rated Torque 2.5 Kgfcm (18 lb. ft.)
T
or
que
Current (Amp.)
7.2
3.6
3.0
0.8
1.0
2.0
1.2
1.4
25.3
3
Torque vs. Current Curve (Typical)
Type: PTB-5BL
(kgfm)
(lb. ft.)
8
4
2
0
0.5
1.0
1.5
3.0
21.7
28.9
36.2
43.4
5.06
57.9
Rated
Current
2.25
Amp
Rated Torque 5 Kgfm (36 lb. ft.)
T
or
que
Current (Amp.)
14.5
7.2
6
2.0
2.5
1
3
5
7
3
Torque vs. Current Curve (Typical)
Type: PTB-10BL
(kgfm)
(lb. ft.)
16
8
4
0
0.5
1.0
1.5
3.0
43.4
57.9
72.3
86.8
101
116
Rated
Current
2.20
Amp
Rated Torque 10 Kgfm (72 lb. ft.)
T
or
que
Current (Amp.)
28.9
14.5
12
2.0
2.5
2
6
10
14
3
Torque vs. Current Curve (Typical)
Type: PTB-20BL
(kgfm)
(lb. ft.)
30
20
15
0
0.5
1.0
1.5
3.5
36.2
72.3
108
144
181
217
Rated
Current
2.75
Amp
Rated Torque 20 Kgfm (144 lb. ft.)
T
or
que
Current (Amp.)
25
2.0
2.5
10
5
3.0
3