Example – Warner Electric PB-1525 User Manual

Page 11

Advertising
background image

11

Warner Electric • 800-825-9050

P-209 • 819-0517

PB-1000 Brake–Heavy Duty

Drawing I-25587

How to Order:

1. Specify Bore Size for Item 2.
2. Specify Inside Mounted for Items 5A and 6A

or Outside Mounted for Items 5B and 6B.

3. Specify Voltage for Item 6A or 6B.
4. See P-1234 for Power Supplies.

Example:

PB-1000 Brake per I-25587 - 90 Volt, 1-1/2" Bore,
Inside Mounted

These units, when used in conjunction with the cor-
rect Warner Electric conduit box, meet the stan-
dards of UL508 and are listed under guide card
#NMTR, file #59164. These units are CSA certified
under file #LR11543.

PB-1000, H.D.

Item

Description

Part Number

Qty.

1

Armature Assembly

5322-111-002

1

1-1

Armature

5322-111-036

1

1-2

Splined Adapter

104-0009

1

1-3

Autogap Accessory

5322-101-004

1

1-4

Screw

797-0272

3

1-5

Locknut

661-0004

3

2

Bushing
1/2" to 1-1/2" Bore
3/4" to 2-11/16" Bore

180-0026 to 180-0056* 1

3

Splined Hub

540-0062

1

4

Retainer Ring

748-0007

1

5A

Mounting Accessory - I.M.

5321-101-001

1

5B

Mounting Accessory - O.M.

5321-101-002

1

6A

Magnet - Inside Mounted

1

6 Volt

5312-631-004

24 Volt

5312-631-005

90 Volt

5312-631-006

†90 Volt LK Facing

5312-631-001

6A-1

Terminal Accessory

5311-101-001

1

6B

Magnet - Outside Mounted

1

6 Volt

5312-631-011

24 Volt

5312-631-013

90 Volt

5312-631-012

†90 Volt LK Facing

5312-631-002

PB-1000, H.D.

Item

Description

Part Number

Qty.

6B-1

Terinal Accessory

5311-101-001

1

7

Conduit Box

5200-101-011

1

*See page 20 for specific part numbers. †Optional LK facing
available.

1

Shipped Assembled

2

3

5A

4

5B

6A

6A-1

6B

6B-1

7

1-3

1-4

1-2

1-1

1-5

7

Advertising