Warner Electric SFC-1525 User Manual

Page 20

Advertising
background image

20

Warner Electric • 800-825-9050

P-207

819-0516

SFC-1000 Clutch Coupling Bearing Mounted

Drawing I-25598

Customer Shall Maintain:

1. Armature mounting shaft concentric with field and

rotor mounting shaft within .006 T.I.R.

2. Angular alignment of shafts within 1/2 degree.

Arm Shaft

.750 – 2.687

Rotor Shaft

.500 – 2.000

Static Torque

240 lb. ft.

Maximum Speed

2,500 rpm

Standard Voltage

D.C. 6, 24, 90

All dimensions are nominal unless otherwise noted.

6.531

1.421

1.546

.937

.062

.562

1.375

.187

.437

1.250

2.562

Dia.

2.062

2.687

2.500

10.328

Max.

Dia.

6.000

Dia.

4.093

Dia.

5.890 Max.

Armature View

See page 28 for details on

Bushings.

Field View

Removable plug in ends for

1/2" conduit.

45°

7.687

.343

.350/.342

See page 28 for details

on Bushings.

3.750

.875

6.125

Advertising