Warner Electric ERDD Sizes 120 to 600 User Manual

Page 5

Advertising
background image

Warner Electric Europe • +33 (0)2 41 21 24 24

P-2064-WE • 2/13 5

6.2

Detection kit

Fitting

Check that the brake is correctly set to the
nominal airgap. Tighten the M5 bolts in the moving
armature then fit the nut (see figure 4), then fix the
sensor using the M5 bolts and washers.

NB : The M3 fixing bolts are self tapping.


Adjustment

Insert a shim 0,15 mm thick near to the bolt
between the face of the inductor and moving
armature. Switch the device on, tighten the bolt
to contact with the sensor until the switch point
is obtained then lock the bolt using the nut.

Check correct operation by making several
successive starts and releases.

Switch characteristics

Protection

IP 65

Temperature

-40°C / +120°C

Cable

3 x 0,75 mm

Switching power: 8A-250VAC / 6A - 380 VAC

Switch connection

M5 screw

Nut

Moving
Armature

Magnet

Switch

Screw
washer M3

X

6.3

Hand release kit


Only for use with VAR02

Fitting: (Fig 5 and 6)


Check that the brake is correctly set to the
nominal airgap.

Fit the spindles in the lever, the springs in the
moving arma ture, then the bolts and washers as
shown in figure 5, res pecting dimension X (See
table 4)

ERD size

060

100

170

300

ERDD HT size

120

200

340

600

Dim. X (+0,2/0 mm)

1

1

1

1,5

Table 4

Fig. 4

Black

Red

Blue

Control position

2 positions

Removable
Handle

Fig. 6

Washerscrew

Hand release

Axle

Spring

X

Fig. 5

Advertising
This manual is related to the following products: