background image

Warner Electric Europe • +33 (0)2 41 21 24 24

P-2081-WE • 2/13 3

2.2

Precautions and safety measures

During the maintenance period make sure

that the moving parts of the machine are

stationary and that there is no risk of start-up.

All intervention have to be made by qualified

personnel, owning this manual.

Any modification made to the brake without

the express authorisation of a representative of

Warner Electric, in the same way than any use

out of the contrac tual specifications accepted

by “Warner Electric”, will result in the warranty

being invalidated and Warner Electric will

no longer be liable in any way with regard to

conformity.

3

Installation

3.1

Transport / storage

These units are supplied as standard in

packaging guaranteeing protection for a period

of 6 months by land or air transport, or after

transport by ship to neighbouring continents

(without crossing the tropics).

3.2

Handling

The clutch is supplied pre-assembled with the

driving flange not fixed.

Avoid any impact on the units so not to alter

their performance.

3.3

Mise en place

The hub (515) is normally supplied at tolerances
H7 for the bote and P9 for the width of the
keyway (In accordance with NF E 22-175/DIN
6885/BS 4235/ISO R773).

The drive flange (529) is generally supplied at a
bore H7 but without fixing holes.

We recommend a tolerance h6 for the shaft and
an adjustment H7/f7 for he drive flange (529).

• Centre the flange (529) on the recieving part,
then fix it with bolts and lock them

• Slide the hub (515) onto the shaft (after
adjusting the keyways) by positioning the teeth
of the outer discs (302) or (305), opposite of the
hollows of the driving flange (529).

In cases where two coaxial shafts are fitted, the

maximum authorised setover is 0,05 mm. The

angular misalignment should not exceed 0,1

mm over a length of 100 mm. If these values

cannot be attained, we recommend that an

elastic coupling is fitted between the drive and

receiving parts.

Do not forget to secure the bolts fixing the

driving flange (529) with Loctite 243 or an

equivalent type of product and tighten them to

torque.

Never directly strike the cylinder (401), closing

flange (408), or hub (515), use a soft alloy block

or drift between these parts and the fitting

device provided.

It is essential to comply with the length

dimension “ L ± 0,5 “ (see table 1) in order to

prevent any risk of contact between the drive

flange (529) and the hub (515).

4

Maintenance

4.1

Maintenance

P130, VAR00/02 series clutches only require low

maintenance because wear in the disc set is

automatically compensated for by movement in

the piston, within the limits of its travel.

It is however necessary to:

• Regularly check the seal of the pressure

chamber and in the event of leakage, or after 5

years use, change the seals (701, 702)

• Check the wear on the disc set, by measuring

the travel of the piston (402), using table 2,

below and the diagrams on annex