Warner Electric 1415-10 Electric Pump Clutch Mounting User Manual

Installation instructions

Advertising
background image

Warner Electric Pump Clutch Mounting

Part No. 1415-4 and 1415-10

Installation Instructions

Introduction

This sheet has been prepared to provide step by
step instructions for assembling/installing
Warner Electric pump clutches. Please follow
the instructions carefully, referring to the explod-
ed view to assemble the clutch.

Failure to follow these instruc-

tions may result in product damage, equip-
ment damage, and serious or fatal injury to
personnel.

Step 1

Assemble pump adapter (2) to mounting bracket
(1) with the two 3/8-16 x 1" Lg. capscrew and
lockwasher sets (3) furnished.

Step 2

Mount the adapter/mounting bracket assembled
in Step 1 to the pump (4) with four 3/8-16 x 1-
1/2" Lg. capscrew and lockwasher sets (3) fur-
nished.

Step 3

Slide field assembly (6) onto pump adapter (2)
and fasten with three socket head screws 1/4-
20 x 3/8" Lg. (7).

2

4

1

5

6

3

7

8

9

12

11

10

Step 4

Slide rotor (8) onto nose of adapter (2). This is a
slip fit and can be pushed on by hand.

Step 5

Expand retaining ring (9) with retaining ring pliers
and install in groove adjacent to rotor bearing in
pump adapter (2). Make sure retaining ring is fully
seated by compressing it into groove with a
screwdriver.

Step 6

Insert key (10) into pump (4) shaft keyway.

Step 7

Slide armature assembly (11) onto pump shaft until
it bottoms against the rotor, then back out .030
inch, measuring this airgap with a thickness gauge
in at least three places.

Step 8

Tighten the three set screws (12) in the armature
hub by inserting an allen wrench through the hole
provided in the pump adapter (2).

The clutch has now been mounted and is ready to
be wired to a power source.