AL2094S Designers Guide

Doc. No. DG_2094E

Altec Electronic AG

Seite 29 / 30



Clearance and creepage between primary (mains) and secondary circuits according EN
60950-1:2001, clause 2.10.3.2 table 2H and clause 2.10.4 table 2L.

Minimum distances between primary and secondary circuits (f.g. for mains voltage 230 V

AC

):

Clearance = 4 mm
Creepage = 5 mm



Failure to maintain these minimum distances would invalidate the approval.

NOTE: For a host or other expansion cards fitted in the host using or generating voltages
greater than 300 V (rms or dc), advice from a competent telecommunications safety
engineer must be obtained.



If these clearance and creepage distances cannot be provided inside the host due to space
limitations, a dielectric material may be used as a physical insulation barrier. The dielectric
material used in this insulation must have a thickness of at least 0.4mm.

After installation (or implementation) of the Socket Modem inside a host system, it is
recommended that a competent telecommunications safety engineer inspects the
complete system to ensure that safety compliance is maintained.



(TNV = Telecommunications Network Voltages)