WARNING:

Setting this value too high may cause the fan to rotate at full speed only

when the CPU is at a very high temperature and therefore cause the

system to be damaged.

The Temperature of Start option can only be set if the Smart Fan control option is set to

Auto PWM Mode. Use the Temperature of Start option to set the CPU temperature at

which the cooling fan starts to rotate using the starting pulse width modulation (PWM)

specified in the Start PWM option below. To set a value, select the Temperature of Start

option and enter a decimal number between 0 and 127. The temperature range is

specified below.

 Minimum Value: 0°C

 Maximum Value: 127°C

 Start PWM [30]

The Start PWM option can only be set if the Smart Fan control option is set to Auto

PWM Mode. Use the Start PWM option to set the PWM start value. To set a value, select

the Start PWM option and enter a decimal number between 0 and 100. The temperature

range is specified below.

 Minimum Value: 0

 Maximum Value: 100

 Slo p e (Du ty Cycle ) [4 (PWM)]

The Slope (Duty Cycle) option can only be set if the Smart Fan control option is set to

Auto PWM Mode. Use the Slope (Duty Cycle) option to select the linear rate at which the

PWM mode increases with respect to an increase in temperature. A list of available

options is shown below: