3 turn off the power, 4 opening the system, 5 replacing components – IEI Integration AFL-ххA-N26 User Manual

Page 64: 1 memory module replacement, Urn off the, Ower, Pening the, Ystem, Eplacing, Omponents

Advertising
background image

AFL-xxA-N26 Series Panel PC

Page 64

4.3 Turn off the Power

WARNING:

Failing to turn off the system before opening it can cause permanent

damage to the system and serious or fatal injury to the user.

Before any maintenance procedures are carried out on the system, make sure the system

is turned off.

4.4 Opening the System

WARNING:

Over-tightening back cover screws will crack the plastic frame.

Maximum torque for cover screws is 5 kg-cm (0.36 lb-ft/0.49 Nm).

To open the system, the back cover and the internal aluminum cover must be removed.

Please follow the instruction described in Section 3.4 to open the system.

4.5 Replacing Components

4.5.1 Memory Module Replacement

The flat panel PC is preinstalled with a 2 GB DDR3 memory module. If the memory

module is fail, follow the instructions below to replace the memory module.

Step 1:

Follow all anti-static procedures. See Section 4.2.

Step 2:

Turn off the power. See Section 4.3.

Step 3:

Remove the back cover and the internal aluminum back cover. See Section 3.4.

Step 4:

Locate the DDR3 SO-DIMM on the motherboard (Figure 4-1).

Advertising
This manual is related to the following products: