IEI Integration AFL2-W19A-H61 v1.11 User Manual

Page 163

Advertising
background image

AFL2-W19A/AB-H61

P a g e 144

Enabled

Enables the Fanless Temp. Overwrite control function.

Disabled

D

EFAULT

Disables the Fanless Temp. Overwrite control function.

 Tem p eratu re Of Fan le s s [32 C]

NOTE:

If the Temperature of Fanless is enabled, the fan will only turn on when

the Environment Temperature 1 reaches to the temperature set in the

following Temperature of Fanless option.

For safety reason, the fan will turn on automatically to cool down the

system when the CPU temperature exceeds 80 ºC, no matter the

Temperature of Fanless is enabled or not.

Use the Temperature Of Fanless option to configure default temperature setting. When

the environment temperature is lower than default temperature setting, the fan will be

switched off. When the environment temperature is higher than default temperature

setting, the fan will be switched on. (The environment temperature depends on the

Environment Temperature 1.) A list of available options is shown below:

Disabled

Disabled the Temperature Of Fanless function

4 C

When the environment temperature is lower than 4 C,

the fan will be switched off.

8 C

When the environment temperature is lower than 8 C,

the fan will be switched off.

12 C

When the environment temperature is lower than 12 C,

the fan will be switched off.

16 C

When the environment temperature is lower than 16 C,

the fan will be switched off.

20 C

When the environment temperature is lower than 20 C,

the fan will be switched off.

Advertising