1 system maintenance introduction, 2 anti-static precautions, Ystem – IEI Integration AFL2-12A-D525 User Manual

Page 65: Aintenance, Ntroduction, Static, Recautions

Advertising
background image

AFL2-12A-D525 Series Panel PC

Page 65

5.1 System Maintenance Introduction

If the components of the AFL2-12A-D525 fail they must be replaced. Components that can

be replaced include:

ƒ SO-DIMM

module

ƒ WLAN

Module

Please contact the system reseller or vendor to purchase the replacement parts. Back

cover removal instructions for the AFL2-12A-D525 are described below.

5.2 Anti-static Precautions

WARNING:

Failure to take ESD precautions during the maintenance of the

AFL2-12A-D525 may result in permanent damage to the

AFL2-12A-D525 and severe injury to the user.

Electrostatic discharge (ESD) can cause serious damage to electronic components,

including the AFL2-12A-D525. Dry climates are especially susceptible to ESD. It is

therefore critical that whenever the AFL2-12A-D525 is accessed internally, or any other

electrical component is handled, the following anti-static precautions are strictly adhered

to.

ƒ Wear an anti-static wristband: - Wearing a simple anti-static wristband can

help to prevent ESD from damaging the board.

ƒ Self-grounding: - Before handling the board touch any grounded conducting

material. During the time the board is handled, frequently touch any

conducting materials that are connected to the ground.

ƒ Use an anti-static pad: - When configuring the AFL2-12A-D525, place it on

an antic-static pad. This reduces the possibility of ESD damaging the

AFL2-12A-D525.

ƒ Only handle the edges of the PCB: - When handling the PCB, hold the PCB

by the edges.

Advertising