Installation, Technical specifications – Lincoln Electric IM10090 ARC TRACKER User Manual

Page 10

Advertising
background image

ARC TRACKER™

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS -

ARC TRACKER™

RATED OPERATING RANGE NEMA EW1

INPUT VOLTAGE AND CURRENT

Model

K3019-1

Volts at Rated Amperes

44 V DC

Amperes

1000 A DC

Duty Cycle

100%

Input Amperes

0.8-0.5 A

Input Voltage ± 10%

120-230 V AC, 50/60 Hz

* All attachment plugs must comply with the Standard for Attachment Plugs and Receptacles, UL498.

RATED OPERATING RANGE IEC60974-1

Volts at Rated Amperes

44 V DC

Amperes

1000 A DC

Duty Cycle

100%

VOLTAGE

50/60 Hz

120

230

230

Input

Amperes

0.8 A

0.5 A

0.5 A

PLUG

NEMA 5-15P (INCLUDED)

ANY NEMA 250 V TYPE*

CEE 7/ 7

INPUT CORD

3 CONDUCTOR, #18 AWG

TYPE S, SO, SOO, ST, STO, STOO OR

EQUIVALENT EXTRA HARD USAGE CORD

3 CONDUCTOR, 1.0 mm

2

HAR

REGION

NORTH

AMERICA

EUROPE

RECOMMENDED INPUT WIRE

PHYSICAL DIMENSIONS

TEMPERATURE RANGES

HEIGHT

12 in (305 mm)

MODEL

K3019-1

WIDTH

9 in (220 mm)

DEPTH

15 in (380 mm)

WEIGHT

20 lbs ( 9 kg)

OPERATING TEMPERATURE RANGE

STORAGE TEMPERATURE RANGE

14°F TO 104°F (-10°C TO 40°C)

-40°F TO 185°F (-40°C TO 85°C)

VOLTMETER

AMMETER

ENERGY

± 2% + 0.1**

± 2% + 2**

± 5%

METER ACCURACY (AS SHIPPED)

**Accuracy is expressed as +/- [Percentage of Reading + Digits].

For example: 10A = +/- 10A x 0.02 + 2 = 10A +/- 2.2, or 7.8A to 12.2A