Enable limits? yes no – Lincoln Electric IM10178 POWER FEED 84 U.I. CONTROL BOX User Manual

Page 60

Advertising
background image

B-24

OPERATION

To set limits, press the desired memory button 1-8 and hold for 5
seconds. Release the memory button when the memory number
begins to blink rapidly and the displays "Memory X Set Limits" as
shown below

If the passcode does not equal zero (0000), enter the passcode now.
If the passcode has been forgotten, a computer application is required
to change the passcode.

If the passcode has been set to zero (0000), the display will show the
following:

• Memory Value

• High Limit

• Low Limit

• Parameter Name

One of these items will flash to indicate which item will change when
the knob is rotated. Press the right button on to select the item to
change.

The Limits Setup menu shows a list of all parameters available for the
weld mode stored in the memory chosen. For example, if limits are
being set for a stick (SMAW) mode, parameters such as Run-in WFS
and Postflow will not appear.

To lock a parameter to a specific value that cannot be changed, set
the high and low limits to the same value.

The memory value must always be less than or equal to the high limit,
and greater than or equal to the low limit.

After setting limits, press the memory button with the number. The
display will ask to save or discard the limit changes just made. Press
the left button (YES) to save and enable the limits and exit. Press the
right button (NO) to exit and leave limits unchanged.

enabling/disabling limits

Limits for each memory may be enabled or disabled by pressing and
hold the appropriate memory button for 10 seconds. Release the
memory button when the display shows “Memory x Limits Enable /
Disable”.

If the passcode does not equal zero, enter the passcode now. If the
passcode is zero (0000), SETUP will light and the display will show:

Press the left button (YES) to enable limits or the right button (NO) to
disable limits. Disabling limits does not change any limits values that
may have been previously set.

POWER FEED 84, POWER FEED 84 DUAL

Memory 5

Set Limits:

Press 5 seconds

HI = 200 LO = 180

Weld WFS

Memory Value

High Limit

Low Limit

Parameter Name

Press to select

item to change

Rotate to

change value

Enable Limits?

Yes No

Press 10 seconds
to enable/disable limts

Memory 6 Limits

Enable / Disable

Advertising